On request
Illustrative image
VICKERS (EATON)
Call
VICKERS (EATON) URT1 06 C 12
#URT1 06 C 12
On request
275752
Manufacturer descriptionURT1 06 C 12 Direct Acting Hydraulic Relief Valve - Hydraulic Actuation, 20gpm Max. Flow Rate, Series: URT1-06
Price on request — a consultant will confirm lead time and terms.
Need to confirm compatibility?
Talk to a technical consultant
VICKERS (EATON) — VICKERS (EATON) URT1 06 C 12
- An integral check valve prevents return flow from the accumulator through the unloading valve
- In an accumulator system, the valve cuts out automatically when the accumulator pressure reaches adjusted maximum
- At cut-in pressure (approximately 85% of adjusted maximum), the valve directs delivery to the accumulator and the hydraulic system automatically
- In a double pump system, the valve automatically sequences the pumps to deliver a large volume of oil at low pressure and a small volume of oil at high pressure
- Models designated €œURT€ have threaded ports and require a separate check valve to function as an unloading circuit
Specifications
| Brand | VICKERS (EATON) |
| Category | HYDRAULIC RELIEF VALVES |
| Series | URT1-06 |
| Fluid compatibility | Hydraulic Oil |
| Adjustable pressure range | 500 psi to 2000 psi (35 bar to 140 bar) |
| Port size | 3/4 NPT |
| Mounting type | System Stack |
| Connection gender | Female |
| Valve type | Unloading Valve |
| Maximum operating temperature | 155 °F |
| Actuation type | Hydraulic |
| Maximum operating pressure | 3000 psi |
| Maximum flow rate | 20 gpm |
| Overall height | 158.8 mm |
| Seal material | Nitrile, PFC |
| Overall width | 77.7 mm |
Related products